Patient Functions

How To: Enroll a Patient

click patient tab.jpg

 

to add a new patient click here V2.jpg

The enrollment window will pop up. Select the tag you wish to use from the drop-down list.

enrolment window.png

enter patient info V2.jpg

 

Patient will now have a status of "Active" and the total number of patients will be displayed on the dashboard. Other patient status are "Bypass" and "Tamper Suspended."

 

How to: Unenroll a Patient

After clicking "OK" you will receive a notification that the patient has been unenrolled. The page will then refresh and the patient will be removed from the patient directory. The tag status will change to "available" meaning it can be used on a new patient.

 

 

How To: Use Bypass

MyChild provides a ByPass that allows you to take a patient out of a protected area without setting off alarms. You must select a departing unit and a destination unit. These can be the same. The patient status changes from “Active” to “Bypass” when a patient is in ByPass.

bypass chart v17.jpg

 

patient functions button V2.jpg

click bypass to continue V2.jpg

 

bypass window V2.jpg

A level one notification will appear on the upper right corner of the screen telling you the Bypass has started once the patient leaves though the first bypass designed door.

bypass started notification and alarm 2.jpg

When the time allotted for the bypass is almost expired, a “BYPASS EXPIRING” alarm is triggered.
 
bypass expiring.jpg
When the timer reaches zero, a “BYPASS EXPIRED” alarm is triggered. All bypass alarms (except BYPASS COMPLETE) allow you to edit the bypass. Changes can also be made on the patient card.
bypass expiring 2.jpg
First, click the "Accept" button, then enter a message and click the green arrow to accept the alarm. The Bypass Expired alarm only happens if the time limit has run out and the patient has not passed through the second bypass designated door. If the patient arrives on time, you will receive a Bypass Complete alarm. This will show up in the upper right corner as a notification as it is a level one alarm. Click on the notification to view the alarm detail. 

bypass complete.jpg

When you complete a bypass by clicking “Complete,” you are acknowledging that the patient has arrived at the destination unit. The patient status will return to "Active".

 

For additional help, call 1-800-776-7328 and press 2 for technical support.

Click here to download PDF.

 

 

 

How To: Suspend Tamper

MyChild provides a suspend tamper function which allows you to remove a tag temporarily without setting off alarms. To remove a cut-band or sensing tag temporarily, put the patient in SUSPEND TAMPER. The patient status changes from “Active” to “Tamper Suspended.”

click suspend tamper on patient functions.jpg

complete suspend tamper details.jpg

When the time allotted for the suspend tamper is almost expired, a “SUSPEND TAMPER EXPIRING” alarm is triggered. When the timer reaches zero, a “SUSPEND TAMPER EXPIRED” alarm is triggered. All suspend tamper alarms allow you to edit the suspend tamper. Changes can also be made on the patient card.
When you click “Complete” to complete a Suspend Tamper, you are acknowledging that the tag is back on the patient.

 

How To: Locate Patient